PCX20 Series

Features

  • Utilizes COM20020 ARCNET® controller
  • Interfaces ARCNET with XT/AT (ISA) bus computers
  • I/O-only mapping reduces bus contention problems
  • No requirement for wait-state arbitration
  • Enhanced software capabilities over earlier generation ARCNET controllers
  • Supports coaxial, fiber optic, and twisted-pair cabling including EIA-485
  • Node address switch selects one of 255 possible station addresses
  • Variable data rates up to 5 Mbps
  • Suitable with all Contemporary Controls MOD HUB and AI Series active hubs
  • CMOS design for low-power consumption

Product Overview

The PCX20 Series of Network Interface Modules (NIMs) offers dependable ARCNET connectivity for XT/AT compatible computers.

This product is designed with the COM20020 ARCNET controller chip. Features include command chaining, sequential access to internal RAM, duplicate node ID detection, and variable data rates up to 5 Mbps. There is no requirement for wait-state arbitration.

Each PCX20 module has two LEDs on the board for monitoring network operation and bus access to the module. It also has an external DIP switch so that node addresses can be easily reassigned without removing the module or opening the computer case.

There are eight models within the PCX20 Series. The PCX20-CXS supports coaxial star configurations requiring external hubs if other than point-to-point communication is needed. The PCX20-CXB accommodates a multidrop or coaxial bus configuration, typically without any hubs. Other versions include the PCX20-FOG-ST for fiber optic cable with ST connectors. The PCX20-TPB supports multidrop twisted-pair cabling using RJ-11 and screw terminal connectors. Two units provide DC-coupled EIA-485 operation: the PCX20-485 allows backplane mode to be controlled by the user's software, while the PCX20-485D forces backplane mode via hardware for those users having legacy software that is incapable of invoking backplane control. The PCX20-485X offers transformer-coupled EIA-485 operation with the backplane mode forced through the hardware.

Ordering Information

Hubs

Model Description Purchase
PCX20-485 20020 DC-coupled EIA-485 NIM allows software control of backplane mode
PCX20-485D 20020 DC-coupled EIA-485 NIM forces backplane mode via hardware
PCX20-485X 20020 AC-coupled EIA-485 NIM forces backplane mode via hardware
PCX20-CXB 20020 coaxial bus NIM
PCX20-CXS 20020 coaxial star NIM
PCX20-FOG-ST 20020 ST fiber optic NIM
PCX20-TPB 20020 twisted-pair bus NIM