A fire is detected within a facility. The fire alarm system sounds an
evacuation signal and relays critical information to a workstation at
the security desk. Because the fire alarm and building automation systems are integrated,
a smoke control sequence is initiated that prevents smoke from spreading throughout the facility
by modulating fans and dampers. Additionally, signals sent to the lighting
and access control systems assure safe egress of the building occupants.
Concurrently, a guard at the security desk uses the workstation to pinpoint
the fire's exact location, prints a map, and has it ready as he meets
the fire department when they arrive on the scene.
An emergency situation similar to this is unpredictable. Choosing the
appropriate fire protection from the right supplier is crucial to ensuring
a proper response. Headquartered in Buffalo Grove, Illinois, Siemens Building
Technologies is a leading supplier of products, services and solutions
for fire alarm and life safety protection, as well as building automation
and security. Recently, Siemens implemented a project to offer their
customers stronger integration between the company's building automation
and fire safety systems. The challenge was to enhance the versatile
APOGEE Insight building automation software to allow facility
operators to monitor and control their automation and life safety systems
from a single workstation platform, as well as share information between
those building systems. "There's an advantage to having this capability,"
says Tom Rule, Product Manager for Siemens. "Using an integrated
system, facility managers can gain a clear picture of the status of
each subsystem within the facility. This allows them to provide a greater
environment of safety, and enhance the productivity of their workforce
by using Insight Life Safety workstations that carry UL Listings for
fire, security, and critical process management applications. In addition,
we are able to retrieve diagnostic information from reports and to
configure the system to automatically initiate control sequences between
building systems."
Let me explain with one example. The Alarm Bar application enables an operator to view the current status of their fire, security, and building automation systems. From the Alarm Bar, operators with proper permissions have the ability to acknowledge events and issue commands to the fire alarm system. The communication technology suitable to create the required connectivity was Ethernet. Siemens supports this technology because it is a worldwide standard, noted for its ease of implementation and use. Ethernet is also more cost-effective, cheaper than any other fieldbus.

A portion of the project required UL 864 Recognition on workstation components for use in fireprotective signaling systems. All components, including workstations, monitors, and Ethernet switches used for communications between workstations, had to pass stringent hardware tests in order to acquire a UL Listing on the system. UL 864 Recognition on the Ethernet switches is required to meet the NFPA 72 code requirements that any communications path used for transmitting critical life safety data be listed for fire-protective signaling use. In the fire alarm industry that communication path is known as the Signaling Line Circuit. "Only if every component from the smoke detector to the workstation used for monitoring the system, including Ethernet switches, is UL Recognized for fireprotective signaling use, can the entire system be considered UL Listed," explains Rule. "If any component on the signaling line circuit is not Recognized, then the Listing for the entire system is lost."
For isolation purposes, every networked Insight workstation that is listed for fire-protective signaling use must be connected to the Ethernet network through one of these special switches. Switches were employed because they can extend network distance beyond a single collision domain compared to repeating hubs while increasing performance. Performance is critical to ensure that emergency messages are delivered as quickly as possible.
In an ideal world, UL Listing for Ethernet equipment would be the norm rather than the exception. Few, if any vendors, wanted to provide and maintain the required listings for this type of equipment. In order to allow Ethernet switches to be powered from the fire alarm panel, with its inherent battery backup power, Siemens sought 24 VDC industrial grade switches. Starting in trade magazines, their efforts led them to search the Internet until they located Contemporary Controls, a company based in Downers Grove, Ill. This company's switches are marketed under the CTRLink® trade name, its new Industrial Ethernet product line. This new product line-from repeating hubs to switching hubs-is designed to enhance system functionality and reduce cost. It provides the customer with features that office-grade equipment lacks. Also, the development of CTRLink coincides with the industry's increasing growth rate of Ethernet products which will continue in the years to follow.
After lengthy discussion, Siemens and Contemporary Controls built a relationship and collaborated to develop a solution. Rule says it was to his company's advantage to use Contemporary Controls' services. "Contemporary Controls was willing to secure and maintain UL 864 Recognition on the Ethernet switches, they had equipment configurations to meet our needs and they were able to provide local technical support." (Figure 2)
By necessity, the companies worked closely together to define system
requirements during the product development cycle. This included the
port count and mix of fiber and copper cabling supported. Also, all
UL 864 requirements would have to be met on the eight-port copper Ethernet
switch and the six-port copper/fiber optic unit. Levels for high-voltage
testing are as follows:
Both switches met these test levels and would be able to withstand any
occurrences on the power or signal lines and continue to function. The
units had to survive specific temperature and humidity conditions: 50°C
and 95° humidity for 24 hours.More important, they had to operate
on a backup power source of 24 VDC supplied by the fire alarm panel.
The design must remain constant. Any hardware change that is made requires
a system retest. Rule says in order to ensure quality and consistency
to their customers, Siemens would rely on Contemporary Controls to offer
that same level of consistency.
The high performance of the switches had to meet the key criteria for
Insight. The criteria is dependability, greater flexibility and ease of
operation.
The EIS8-100T provides eight 0/100 Mbps copper ports utilizing RJ-45 connectors.
The EIS6-100T/FT is a similar design but with only four copper ports and
two fiber optic ports utilizing ST connectors. The fiber optic units can
be deployed over long distances (up to 2 km) and in locations where high
noise immunity is desired. The switches offer wide range AC/DC operation.
But for this application, the switches only need to operate from lowvoltage
DC power. The units are mounted in a special enclosure that is also UL
Recognized for fire-protective signaling use. An MTBF of more than 40
years enable these units to be used with confidence.
The APOGEE system architecture is flexible. Workstations communicating
over Ethernet can be positioned side-by-side or could be miles apart.
Additionally, a combination of Fire workstations, which are Listed for
protective-signaling use, and non-Fire workstations that are not, can
reside on the same network (Figure 3). The fire alarm system can only
be controlled from Fire workstations, but data can be monitored from
both Fire and non-Fire workstations.
Fire, security and automation systems can be managed from APOGEE Insight
workstations. The APOGEE system enables data from all connected systems
available to all workstations on the network. For greater efficiency,
a database server centrally administrates the networked system over
a Management Level Network (MLN) that sends information where it needs
to go without encumbering every workstation with unnecessary data.

Rule says users are assigned access privileges that dictate what they
can and can't observe. "This permits the flexibility for centralized
monitoring and/or widespread distribution of information."
UL Listed Fire workstations are typically located within the facility
or campus where the fire alarm system is installed; however, customers
often want the ability to monitor their systems remotely over the Internet
as well. APOGEE is flexible enough to provide this capability too.
Insight Life Safety workstations can be a part of a dedicated network
of Insight workstations or they can be part of a customer's enterprise
(or corporate) network. When connected to a corporate network, the Insight
workstations must reside on a dedicated IP subnet/ broadcast domain
isolated from the corporate network. Rule says this is accomplished
by using a router which prevents traffic from the corporate network
(i.e. broadcasts and other non-Insight messages) from interfering with
the ability for fire alarm signals to pass between Fire workstations.
He explains that this ensures all of the bandwidth on the dedicated
network is available for Insight communications. This configuration
increases data throughput and eliminates security issues that could
arise.
The system architecture locks together through the switches. Typically,
one switch is located at each Insight Fire Workstation on a Management
Level Network. A multiple of EIS8-100T's, connected by Category 5 cabling,
are employed when these workstations are short distances apart
on the network-under 300 m. Segment lengths cannot exceed 100 m requiring
the use of multiple switches. The EIS6-100T/FT, for distances up to
2 km, provides interference-free fiber medium for connecting these workstations.
Typically one workstation is installed at the security desk so the operator
may take appropriate action to any life safety, security, or automation
related events. Copper or fiber connection to the next workstation is
determined by distance. The APOGEE workstations all reside on the Ethernet
network and serve the purpose of monitoring operation and annunciating
critical information. Ultimately, they are tied into the fire panels
via a Siemens proprietary network. In some facilities, 20 or more workstations
might be installed.
Rule says one workstation is often positioned for facilities maintenance
department use in order to ensure that maintenance has first hand knowledge
of any activations or faults on the fire alarm system. By having fire
alarm information available within their building automation management
system, the maintenance staff can immediately determine the precise
location of any problem and make adjustments as necessary. This eliminates
the need for security to communicate the need for action on
the fire alarm system to the facilities maintenance staff and expedites
the return to normal operation.

Additional workstations might also be installed at a facilities director's office or at critical points within the facility that are most effected by operation of various building systems. By having access to information from all building systems within a network of building management workstations, people associated with a facility can get access to the information they need, when and where they need it, to ensure the optimal performance of the facility.
Reliability was vital in this project because it is a life safety system.
The point is, Siemens had to be assured that the life safety system
would continue to function as intended, to save lives and minimize damage
to the facility. "By working with Contemporary Controls we felt
confident that our life safety system would not fail us," says
Rule. In conclusion, Rule adds that the systems Siemens provides must
work as advertised every time. "If one does go down we need to
know that replacement parts are available," says Rule. "We
count on Contemporary Controls to provide reliable products and to have
parts and expertise available at all times." Contemporary Controls
is doing just that.
Unsere Ingenieure helfen Ihnen bei Ihren technischen Fragen.
Besuchen Sie unsere Kontakt Seite fuer mehr Informationen.