About UL Recognized Components

Contemporary Controls has several product lines that are authorized to bear the UL Recognized Component Marking. These products have met the stringent tested required by Underwriters Laboratories. When customers use our UL Recognized Components, they can be confident that our product will pass the rigorous testing required to get their final product UL Listed.

Featured Products

The Skorpion Series

- UL 508 Recognized Component

- Provides Plug and Play Ethernet switch connectivity for automation systems

- Compact Size

 

The EIS Ethernet Interconnect Switch

- UL 864 and UL 1604 Recognized Component

- Auto-negotiated data rate, duplex and flow control on twisted-pair ports

- Broadcast storm control

The EISM5 Miniature Series

- UL1604 Class 1, Div. 2 hazardous rating

- Accommodates up to five 10/100 Mbps twisted-pair ports

- Plug and Play operation

UL 1604

UL 1604 covers electrical equipment and accessories for controlling various industrial equipment in hazardous locations. Class I hazardous locations are those where fire or explosion hazards may exist due to the presence of flammable gases, vapors, or flammable liquids. Such equipment has been investigated for risks to life and property in accordance with these standards:

        ANSI/ISA-12.12.01 — Nonincendive Electrical Equipment
        ANSI/NFPA 497 — Flammables and Hazardous Locations
        NFPA 70 — National Electrical Code, Articles 500, 501 & 505
        UL 508 — Industrial Control Equipment

The EISM5-100T and all models of the EIS Ethernet Interconnect Switch Series qualify for use in Class I, Division 2 hazardous locations (Groups A, B, C, D). UL 1604 Certification for these models can be viewed here.

UL 864 9th Edition

UL 864 9th Edition governs the safety of fire alarm systems and equipment, including smoke detectors, sprinkler systems and fire alarms in accordance with these standards:

        NFPA 12, Carbon Dioxide Extinguishing Systems
        NFPA 12A, Halon 1301 Fire Extinguishing Systems
        NFPA 13, Installation of Sprinkler Systems
        NFPA 15, Water Spray Fixed Systems for Fire Protection
        NFPA 16, Installation of Foam-Water Sprinkler and Foam-Water Spray Systems
        NFPA 17, Dry Chemical Extinguishing Systems
        NFPA 17A, Wet Chemical Extinguishing Systems
        NFPA 70, National Electrical Code
        NFPA 72, National Fire Alarm Code
        NFPA 92A, Recommended Practice for Smoke-Control Systems
        NFPA 92B, Guide for Smoke Management Systems in Malls, Atria, and Large Areas
        NFPA 2001, Clean Agent Fire Extinguishing Systems

The EIS Ethernet Interconnect Switch series is authorized to carry the UL 864 9th Edition Recognized Component Marking.

 