Convenient Wireless Network Setup Using the BAScontrol22 for Training and Education

Networking and automation equipment in the HVACR classroom/lab has always been important because instructors rely on it to provide experiential evidence for theoretical knowledge. Modern HVACR classrooms use technology to network, control and analyze automation processes and require equipment which is intuitive and easy to use and understand by students. Equipment which is difficult to…

Continue Reading

Easy Wired or Wireless Thermostat Application with BACnet Supervision

Contemporary Controls offers two BASstat —  BACnet-networked communicating thermostat models that provide customers with flexibility when installing a distributed zone thermostat control system. Depending on parameters such as building zone layout, existing EIA-485 cabling, Wi-Fi routers in place, and connection distance requirements between BASstat thermostats and BASview3 supervisory device, each BASstat model offers distinct benefits…

Continue Reading

What is Wi-Fi 6?

What is new and different with Wi-Fi 6? Well, first let’s start with what is still the same – there are still the traditional Wi-Fi clients and access points (APs) which they connect to. Physically, the hardware for Wi-Fi 6 is actually pretty similar, so device manufacturers can lean on the antenna design experience they…

Continue Reading

Edge Computing Explained

IBM’s edge computing definition: “Edge computing places networked computing resources as close as possible to where data is created. Edge computing is an important emerging paradigm that can expand your operating model by virtualizing your cloud beyond a data center or cloud computing center. Edge computing moves application workloads from a centralized location to remote…

Continue Reading

Benefits of Cloud Connected Buildings

As any new technology that disrupts the way we do things makes its way into our lives, we are faced with adopting to the rapid changes it introduces. As new ground-breaking tech enters an industry, it will “shake things up” and possibly create entire new industries around it. This is the case with cloud computing….

Continue Reading

BASgateway EnOcean – BACnet to EnOcean Gateway Programmable Controller

Contemporary Controls is releasing a new product this year! You get to have a sneak peak in this article. Consolidate your EnOcean wireless sensor and switch data to BACnet systems with the Contemporary Controls BASgateway EnOcean. EnOcean wireless energy-harvesting devices are freely-positionable, self-powered, and suitable for retrofits and newly constructed buildings. EnOcean technology provides high…

Continue Reading

Notes from the Field Episode 003 -Heat Pump w/ Woodstove Preheat BAScontrol22

We see the BAScontrol series used in commercial HVAC applications all of the time, but not so often in home automation. This Heat Pump w/ Woodstove Preheat home automation application uses the rugged BAScontrol22 for control and a Niagara JACE for supervision over BACnet/IP.     Thanks to its unrestricted, unlicensed nature, free software tools,…

Continue Reading

BACnet Diagnostics and Troubleshooting with BASrouter 3.0

The Contemporary Controls BASrouter is BTL Listed with both B-RTR and B-BBMD device profiles to ensure seamless integration into BACnet networks. This rugged and compact BACnet multi-network router provides versatile stand-alone routing between BACnet/IP, BACnet Ethernet (ISO 8802-3), and BACnet MS/TP networks. In addition to its field-proven operation, the BASrouter has a number of diagnostic…

Continue Reading