Configurable I/O BACnet/IP or Modbus TCP

BACnet IP I/O Modules

 

iSMA Configurator

iSMA Configurator Data Sheet

iSMA Configurator Manual

  Introduction to the iSMA Configurator Software


To download the iSMA Configurator, please register.

 

 

Product Overview

The configurable I/O modules provide universal inputs that support temperature, analog, resistance and binary in a single module. For applications not requiring universal inputs there are modules with discrete inputs that support contact closure and retentive pulse counting at 100Hz. Additional modules supply a mix of universal and/or discrete inputs with relay outputs and analog outputs. A single module supports BACnet MS/TP or Modbus RTU/ASCII with a simple dip switch selection.

The modules are housed in a compact UL approved self-extinguishing plastic enclosure, rated for operation in -10°C to +50°C (14°F to 122°F) environments and DIN rail or panel mounted typically in a control enclosure. All modules use half-wave rectified low voltage power supply that allows for sharing of power with other 24 VAC/VDC devices. All IP version modules are equipped with a built-in Modbus TCP/IP for RS485 gateway which allows for establishing a connection with RS485, additional I/O modules, or 3rd party devices.

Product Details

  • BACnet/IP and Modbus TCP communication protocols in a single module dip switch selectable
  • Universal Inputs for temp, analog, resistance, binary with up to 16-bit resolution
  • Supported temperature sensors in Fahrenheit and Celsius degrees
  • All Digital Inputs work as retentive counters up to 100 Hz
  • Digital Outputs 24 VAC or 30 VDC max. 3 A or 8 A
  • Triac Outputs: 0.5 A @ 24 VAC
  • Analog Output with max. 10 VDC and 20 mA load allows control of relays or SSR with PWM
  • LEDs for - inputs, outputs, power and communications status
  • Removable terminal strips
  • 24 V AC/DC Input Power
  • DIN rail or panel mounting
  • Operating temperature: -10°C to 50°C (14°F to 122°F)
  • Ingress Protection Rating: IP40 – for indoor installation
  • Manual output override switches on 4 and 8 point units
  • Built-in light, cooling and heating control modes (select units)
  • Built-in Modbus Gateway TCP/IP to RS485
  • Simple and fast addressing from 1 to 99

Configuration Software

The iSMA Configurator has been designed to perform configuration, firmware updates and diagnostics on the configurable I/O. The free downloadable software provides communication with the use of USB, BACnet MS/TP, Modbus RTU, BACnet IP or Modbus TCP. It allows monitoring the device's operating parameters, remote change of I/O module output states and input modes. This simple and intuitive to use software is the convenient tool for every configurable I/O user. This software is intended for Windows operating system and can be run on Windows 7, 8 or 10. There is no need to install any additional software or drivers to run iSMA Configurator.

  • Connection by USB cable without powering the module
  • Upgrade firmware, reset module, reload module and load default settings
  • Monitor digital inputs/pulse counter values
  • Configure universal inputs for temp, analog, contact closure
  • Establish COV increments
  • Configure communication parameters
  • Save configuration file, load configuration file
  • Supported five types of communication: Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, USB
  • Web based browser configuration

Selection Guide

Model   UI     DI     AO     DO     TO     HOA  
iSMA-B-8I-IP 8
iSMA-B-8U-IP 8
iSMA-B-4I4O-H-IP 4 4* Yes
iSMA-B-4U4O-H-IP 4 4* Yes
iSMA-B-4U4A-H-IP 4 4 Yes
iSMA-B-4O-H-IP 4** Yes
iSMA-B-4TO-H-IP 4 Yes
iSMA-B-MIX18-IP 5 5 4 4*
iSMA-B-MIX38-IP 8 12 6 12*

UI = Voltage/Current/Resistive/Dry Contact
DI = Dry Contact/Fast pulse counter (100 Hz)
AO = Analog Out 10V, 20 mA max/PWM
DO* = (NO) 3A @ 24 VAC/30 VDC
DO** = (NO/NC) 8A @ 24 VAC/30 VDC
HOA = Hand-Off-Auto-Switch

Input Modules

iSMA-B-8I-IP provides 8 Digital Inputs (DI) for Dry contact inputs and Fast pulse counter up to 100 Hz that can be saved in EEPROM memory.

  • One 10BASE-T/100BASE-TX Ethernet port BACnet/IP or Modbus TCP

iSMA-B-8U-IP provides 8 Universal Inputs (UI). All Universal Inputs have 12-bit or 16-bit resolution which supports the following types of inputs:

  • Temperature Input supports the following types of sensors:
    • In Fahrenheit degrees: 10K Type2, 10K Type3, 20K, 3K, PT 1000, Ni 1000 32F, Ni 1000 70F
    • In Celsius degrees: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 0C, Ni 1000 20C, Ni1000 LG 2.
  • Voltage input 0-10 VDC: input resistance 100 kΩ accuracy ±0.1%, measurement resolution 3 mV @ 12-bit and 1 mV @ 16-bit
  • Current input 0-20 mA external 200 Ω resistor required, provided with module
  • Resistive input 0-1000 kΩ: measurement resolution for 20 k⊃ load 20 Ω @ 12-bit and 1 Ω @ 16-bit
  • Dry contact input
  • One 10BASE-T/100BASE-TX Ethernet port BACnet/IP or Modbus TCP

Output Modules

iSMA-B-4O-H-IP provides 4 relay (NC/NO) contacts rated max. 8 A @ 24 VAC/30 VDC with Hand Off Auto switch.

  • One 10BASE-T/100BASE-TX Ethernet port BACnet/IP or Modbus TCP

iSMA-B-4TO-H-IP provides 4 triac outputs rated 0.5 A @ 24 VAC with Hand Off Auto switch.

  • One 10BASE-T/100BASE-TX Ethernet port BACnet/IP or Modbus TCP

Mixed Modules

iSMA-B-4I4O-H-IP provides:

  • 4 digital Inputs (DI) for Dry contact inputs and Fast pulse counter up to 100 Hz that can be saved in EEPROM memory and
  • 4 relay (NO) contacts rated max. 3 A @ 24 VAC/30 VDC with Hand Off Auto switch
  • One 10BASE-T/100BASE-TX Ethernet port BACnet/IP or Modbus TCP

iSMA-B-4U4O-H-IP provides:

  • 4 Universal Inputs (UI) with the functionality as described in the iSMA-B-8U and
  • 4 relay (NO) contacts rated max. 3 A @ 24 V AC/30 VDC with Hand Off Auto switch
  • One 10BASE-T/100BASE-TX Ethernet port BACnet/IP or Modbus TCP

iSMA-B-4U4A-H-IP provides:

  • 4 Universal Inputs (UI) with the functionality as described in the iSMA-B-8U
  • 4 Analog Outputs 12-bit AD Analog Output with max. 10 VDC and 20 mA load allows control of relays or SSR with PWM
  • One 10BASE-T/100BASE-TX Ethernet port BACnet/IP or Modbus TCP

iSMA-B-MIX18-IP provides:

  • 5 Universal Inputs (UI) with the functionality as described in the iSMA-B-8U,
  • 5 Digital Inputs (DI) for Dry contact inputs and Fast pulse counter up to 100 Hz save in EEPROM memory
  • 4 relay (NO) contacts rated max. 3 A @ 24 VAC/30 VDC
  • 4 Analog Outputs 12-bit AD Analog Output with max. 10 VDC and 20 mA load allows control of relays or SSR with PWM
  • Two 10BASE-T/100BASE-TX Switched Ethernet ports BACnet/IP or Modbus TCP

iSMA-B-MIX38-IP provides:

  • 8 Universal Inputs (UI) with the functionality as described in the iSMA-B-8U,
  • 12 Digital Inputs (DI) for Dry contact inputs and Fast pulse counter up to 100 Hz save in EEPROM memory and
  • 12 relay (NO) contacts rated max. 3 A @ 24 VAC/30 VDC and
  • 6 Analog Outputs 12-bit AD Analog Output with max. 10 VDC and 20 mA load allows control of relays or SSR with PWM
  • Two 10BASE-T/100BASE-TX Switched Ethernet ports BACnet/IP or Modbus TCP

Ordering Information

IP I/O Module with BACnet/IP and Modbus TCP (with built in Modbus Gateway to RS485)

Model Description    
iSMA-B-8I-IP 8DI - with BACnet/IP and Modbus TCP (plus Gateway) $270
iSMA-B-8U-IP 8UI - with BACnet/IP and Modbus TCP (plus Gateway) $353
iSMA-B-4I4O-H-IP 4DI and 4DO with HOA - with BACnet/IP and Modbus TCP (plus Gateway) $324
iSMA-B-4U4O-H-IP 4UI and 4DO with HOA - with BACnet/IP and Modbus TCP (plus Gateway) $353
iSMA-B-4U4A-H-IP 4UI and 4AO with hand operation - with BACnet/IP and Modbus TCP (plus Gateway) s $363
iSMA-B-4O-H-IP 4DO relay NC/NO 8 A @ 30V AC or DC with HOA - with BACnet/IP and Modbus TCP (plus Gateway) $324
iSMA-B-4TO-H-IP 4TO triac outputs- .5 A @ 30 V AC with HOA - with BACnet/IP and Modbus TCP (plus Gateway) $324
iSMA-B-MIX18-IP 5DI, 5UI, 4AO, 4DO - with BACnet/IP and Modbus TCP (plus Gateway) $460
iSMA-B-MIX38-IP 12DI, 8UI, 6AO, 12DO - with BACnet/IP and Modbus TCP (plus Gateway) $593

Accessories

Model Description    
AI-XFMR Wall-mount plug-in transformer 120 VAC (nom) input/24 VAC (nom) output (details...) $45
AI-XFMR-E Wall-mount plug-in transformer 230 VAC (nom) input/24 VAC (nom) output (details...) $62
MDR-20-24 24VDC 20W DIN RAIL POWER SUPPLY (details...) $46
MDR-40-24 24VDC 40W DIN RAIL POWER SUPPLY (details...) $57
SDR-75-24 24VDC 75W DIN RAIL POWER SUPPLY (details...) $102

Spare Terminal Strip Connectors

Model Description    
iSMA-B-8I-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-8I / ISMA-B-8I-IP module types. $20
iSMA-B-8U-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: ISMA-B-8U / iSMA-B-8U-IP module types. $20
ISMA-B-4I4O-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4I4O-H / iSMA-B-4I4O-H-IP module types. $20
ISMA-B-4U4O-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4U4O-H / iSMA-B-4U4O-H-IP module types. $20
ISMA-B-4U4A-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4U4A-H / iSMA-B-4U4A-H-IP module types. $20
ISMA-B-4O-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4O-H / iSMA-B-4O-H-IP module types. $20
ISMA-B-4TO-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-4TO-H / iSMA-B-4TO-H-IP module types. $20
iSMA-B-MIX18-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-MIX18 / iSMA-B-MIX18-IP module types. $26
iSMA-B-MIX38-TB Accessory - complete set of spare plugs, containing all types of plug connectors in necessary amounts for: iSMA-B-MIX38 / iSMA-B-MIX38-IP module types. $35

Related Products

Model Description                  
EISK5-100T Five-port 10BASE-T/100BASE-TX Skorpion switch, DIN-rail mount $127
EISK8-100T Eight-port 10BASE-T/100BASE-TX Skorpion switch, DIN-rail mount $193
EISK16-100T Sixteen-port 10BASE-T/100BASE-TX Skorpion switch, DIN-rail mount $363
BASGSX-M1 BASgatewaySX Modbus to BACnet Gateway DIN-rail Mount with SSL $546
BASGSX-M1/P BASgatewaySX Modbus to BACnet Gateway Panel Mount with SSL $546