When our customers need to quickly get Modbus data from their mechanical devices up to the BACnet/IP infrastructure they use our BASgatewayLX. Customers benefit from the Modbus to BACnet Gateway when using external Modbus serial and TCP because the discovery of Modbus data points appears as quick as configuring BACnet points - greatly reducing the time to discover Modbus devices in the field. BASgatewayLX hosted Modbus device profiles do not require any configuration of points. Just load the proper Modbus device profile and the Modbus points in your Modbus devices will be made available as discoverable BACnet points.
The BASgatewayLX supports up to 30 Modbus serial devices with each device appearing as an individual BACnet device. Each one of the attached devices supports RTU and ASCII serial along with Modbus TCP slave devices attached over Ethernet. The BASgatewayLX functions as a master to all slave devices. Collectively, all the Modbus TCP and Modbus serial devices are assigned to a virtual BACnet network number during configuration.
Using our BASgatewayLX to integrate Modbus devices can't get any easier because our sales manager, Joe Stasiek, has developed a Modbus Device Profile Library for more than 100 popular product models. And if your product model isn't in the library, all it takes is a call to Joe to have that profile to be created.
Having Joe create the device profile relieves you of developing the Modbus point list, so you don't have to be concerned about double wide reads and writes and high/low reads vs. low/high. Joe takes care of all of that, allowing you to just download the profile into the BASgatewayLX and check off only the registers that need to be scanned.
For the systems integrators who want the capability to make their own profiles or modify profiles in the field, we have published an application note that defines the data format we use when developing device profiles.
Internal Web Server
The BASgatewayLX collects data from the Modbus slave devices and status of this can be seen through the internal web server.
Supports Virtual Routing
Through virtual BACnet routing, each uniquely addressed Modbus slave device appears as an individual BACnet device with a unique BACnet device instance. This makes adding multiple Modbus devices with identical device profiles to the same BASgatewayLX simple. More importantly, this allows you to cut/paste identical devices in your head-end.
Easy Configuration
Configuring the BASgatewayLX is easy. Using your browser, open the BASgatewayLX home page. Select the "Configuration" tab and then "Add" a device. After submitting these quick, easy settings, the Modbus variables are now accessible as BACnet object instances. For more information, see the BASgatewayLX configuration video with this issue.
Key Product Features
Visit the BASgatewayLX product page to learn more.