EnOcean to BACnet Gateway

Product Overview

Integrate your EnOcean wireless devices to BACnet systems with the Contemporary Controls' bidirectional EnOcean to BACnet Gateway.

The EnOcean to BACnet Gateway provides the systems integrator with a flexible building block when integrating EnOcean wireless devices to BACnet/IP networks or expanding the number of EnOcean points in an existing building automation system. Thanks to our use of virtual routing technology, our gateway allows building automation supervisors to seamlessly discover EnOcean devices via BACnet because each device will appear as separate BACnet-compliant devices. The gateway creates a set of BACnet objects, specific for each EnOcean Equipment Profile (EEP), and decodes the received EnOcean data into standard BACnet objects, such as analog-inputs for temperatures, humidity, light levels, etc. and multistate objects for EnOcean values that represent multiple states, for easy integration to BACnet system — saving the head-end from decoding the transmitted EnOcean data.

The EnOcean to BACnet Gateway provides the ultimate in flexibility. It features EnOcean device discovery with built-in EEP and web-page configuration using a common web browser. There are no external tools required for configuration. This allows EnOcean devices to be easily combined with BACnet devices and supervisors into one automation system.

Using remote commissioning the gateway can configure EnOcean output devices to be controlled by specific input devices. This can save you from the manual linking that requires repeatedly pressing buttons on the EnOcean devices until they are linked and can make installation of EnOcean devices much easier.

All models feature an SMA connector that supports a stick antenna or an antenna with 2 m cable for mounting the antenna outside the control cabinet. Antenna sold separately.

Model BASGE-EN902 uses 902 MHz for the North American market. Model BASGE-EN868 uses 868 MHz for the European and Chinese market.

Versatile Gateway

  • Bidirectional gateway functionality between EnOcean Wireless and BACnet/IP
  • EnOcean device discovery
  • Remote commissioning of link tables and configuration settings
  • Each EnOcean device appears as virtual BACnet device to aid in integration
  • Received EnOcean data is decoded into standard BACnet objects
  • Built-in EnOcean Device Profiles for seamless integration
  • Webpage configuration—no external tools or software required

Convenient Installation

  • 10/100 Mbps Ethernet with auto-negotiation and Auto-MDIX
  • 24 VAC/VDC powered
  • DIN-rail or panel mounting
  • EnOcean SMA connector provides flexible antenna options

Ordering Information

Model Description                  
BASGE-EN902 EnOcean to BACnet Gateway 902 MHz (North American Version)
Note: An antenna is required but not included. Be sure to purchase either the BASGE-ANT902 or the BASGE-ANT-2M (listed below).
$480
BASGE-EN868 EnOcean to BACnet Gateway 868 MHz (European Version)
Note: An antenna is required but not included. Be sure to purchase either the BASGE-ANT868 or the BASGE-ANT-2M(listed below).
Visit EMEA Store

Antennas

Model Description                  
BASGE-ANT902 EN902 stick antenna (details...) $33
BASGE-ANT868 EN868 stick antenna (details...) Visit EMEA Store
BASGE-ANT-2M EnOcean antenna with 2m cable (details...) $38

Accessories

Model Description    
AI-XFMR Wall mount plug in transformer 120VAC input/24VAC output (details...) $45
AI-XFMR-E Wall mount plug in transformer 230VAC input/24VAC output (details...) $62
MDR-20-24 24VDC 20W DIN RAIL POWER SUPPLY (details...) $46
MDR-40-24 24VDC 40W DIN RAIL POWER SUPPLY (details...) $57
SDR-75-24 24VDC 75W DIN RAIL POWER SUPPLY (details...) $102