For those installations that support a fieldbus solution such as Modbus RTU, Contemporary Controls provides solutions for expanding the number of I/O points in the field. These compact cost-effective modules are available with analog and digital inputs and outputs in varying combinations.
MR-DI4
The Modbus module with 4 digital inputs is designed for local
switching operations. It is suitable to record potential-free switching
states as for example electrical limit switches of ventilation
valves or auxiliary contacts of power contactors. The inputs can
be operated by potential-free switches or contacts and as voltage
inputs. The inputs can be scanned via a Modbus-Master. Setting of
the slave address, bit rate and parity is done with the two address
switches (x1 / x10) on the front. Possible settings are addresses
00 to 99 and baud rates 1200, 2400, 4800, 9600, 19200, 38400,
57600 und 115200 Bd.
MR-DI10
The Modbus module with 10 digital inputs is designed for local switching operations. It is suitable to record potential-free switching states as for example electrical limit switches of ventilation valves or auxiliary contacts of power contactors. The inputs can be operated as contact and voltage inputs (A1, 24VAC/DC, jumper J - A2) or with actuation to GND (A2, jumperJ - A1), depending on the setting of the jumper J. The inputs can be scanned via a Modbus-Master. Setting of the slave address, bit rate and parity is done with the two address switches (x1 / x10) on the front. Possible settings are addresses 00 to 99 and bit rates 1200, 2400, 4800, 9600, 19200, 38400,
57600 und 115200 Bd.
MR-S14
The Modbus module with 4 S0 inputs to DIN EN 62053-31 class A was developed for decentralized switching tasks. It is suitable for counting S0 counter pulses. This allows very good integration of the module into an energy controlling system. In case of a power failure, the last counter readings are saved. The inputs can be scanned by means of standard objects via a Modbus master. The module address, the baud rate and the parity are set by means of two address switches on the front.
MR-AI8
The Modbus module with 8 individually configurable resistance or voltage inputs is designed for local switchingoperations. It is suitable to record resistance or voltage values offor example passive and active temperature sensors electricalventilation or mixing valves, valve positions etc. The inputs areuniversally configurable and can be scanned via a Modbus-Master.Setting of the slave address, bit rate and parity is done with the two address switches (x1 / x10) on the front. Possible settings are addresses 00 to 99 and baud rates 1200, 2400, 4800, 9600, 19200, 38400, 57600 und 115200 Bd.
MR-DO4
The Modbus modules with 4 digital outputs are designed for local switching operations. They are suitable to operate electrical components such as motors, contactors, lamps, sun-blinds etc. We recommend to protect the relay contacts additionally by a RC-element for high inductive loads. MR-DO4 is equipped with a manual control facility for manual switching of the relays.
MR-AO4
The Modbus module with 4 analog outputs is designed for local switching operations. It is suitable as variable encoder, for example ventilation or mixing valves, valve positions etc. The outputs can be adjusted via a Modbus-Master. Setting of the slave address, bit rate and parity is done with the two address switches (x1 / x10) on the front. Possible settings are addresses 00 to 99 and bit rates 1200, 2400, 4800, 9600, 19200, 38400, 57600 und 115200 Bd.
MR-DIO4/2
The Modbus module with 4 digital inputs and 2 relay outputs is designed for local switching operations. It is suitable to receive for example light switches and window contacts in a room and to operate two light bands or to be used as sunblind control. It can also be used to control two motor driven fire dampers or for many other applications. We recommend to protect the relay contacts additionally by a RC-element or high inductive loads. The relays are provided with a manual control facility. Depending on the position of the jumper (below the faceplate) the inputs can be operated as contact and voltage inputs (A1, 24 V AC/DC; jumper J - A2) or with actuation to GND (A2; jumper J - A1. Inputs and outputs can be operated and scanned via a Modbus-Master. Setting of the slave address, bit rate and parity is done with the two address switches (x1 / x10) on the front. Possible settings are addresses 00 to 99 and bit rates 1200, 2400, 4800, 9600, 19200, 38400, 57600 und 115200 Bd.
NG-4 Gray
The NG4 power supply supplies regulated direct voltages for
supplying power to the respective devices of the product family of I/O
components. The device supplies regulated direct voltage 24 V DC at
a power of 16 watts. A parallel operation of several power supply units
is not allowed. The secondary voltage can only be tapped at the right
side of the plug connector and at the screw-type terminals on the top
of the module. The bus communication is looped through on both
sides of the plug connectors.
Input Modules |
|||
| Model | Description | ||
| MR-DI4 | Modbus RTU 4 Digital Inputs | $193 | |
| MR-DI10 | Modbus RTU 10 Digital Inputs | $214 | |
| MR-SI4 | Modbus RTU 4 Retentive Pulse Counting Inputs | $303 | |
| MR-AI8 | Modbus RTU 8 Resistance or Voltage Inputs | $337 | |
Output Modules |
|||
| Model | Description | ||
| MR-DO4 | Modbus RTU 4 Digital Relay Outputs w/ HOA | $233 | |
| MR-AO4 | Modbus RTU 4 Analog Outputs 0 to 10VDC | $243 | |
Mixed Input and Output Modules |
|||
| Model | Description | ||
| MR-DIO4/2 | Modbus RTU 4 Digital Inputs & 2 Relay Outputs w/ HOA | $266 | |
Accessories |
|||
| Model | Description | ||
| AI-XFMR | Wall mount plug in transformer 120VAC input/24VAC output (details...) | $43 | |
| AI-XFMR-E | Wall mount plug in transformer 230VAC input/24VAC output (details...) | $60 | |
| NG-4 Gray | Power Supply Input 110-250VAC Output 24VDC 700mA | $176 | |
| KIT-4POS-IOP | 4-Pole terminal block for I/O Modules qty. 10 | $19 | |
| KIT-4POS-IOJ | 4-Pole Jumper Plug for I/O Modules qty. 10 | $19 | |
| MDR-20-24 | 24VDC 20W DIN RAIL POWER SUPPLY (details...) | $44 | |
| MDR-40-24 | 24VDC 40W DIN RAIL POWER SUPPLY (details...) | $54 | |
| SDR-75-24 | 24VDC 75W DIN RAIL POWER SUPPLY (details...) | $99 | |